NTI E-LD50-100 Liquid Detection Sensor, Cable 50ft 2-Wire Cable 100ft

NTI

$542.00
Part Number:
E-LD50-100
Availability:
Usually ships the same day
1:
For Detecting Water Presence & Warning of Flooding
2:
100% Waterproof Electronics
3:
Detects Any Conductive Liquid or Moisture
4:
Free 15-Day Trial (See below FAQ)
5:
Free Shipping
6:
2-Year NTI Warranty
ADD OPTIONS:
NTI E-LD50-100 Liquid Detection Sensor, Plenum Rope-Style - Length of water sensor cable - 50 ft. Length of 2-wire cable - 100 ft.

This NTI E-LD50-100 Liquid Detection Sensor, Plenum Rope-Style - Length of water sensor cable - 50 ft. Length of 2-wire cable - 100 ft. Connect the liquid detection sensor E-LD (E-LDx-y, E-LD-LCx-y, E-CDx-y) to a set of terminals (1-5) marked "DIGITAL IN". The twisted orange sensing cable should be placed flat on the surface (usually the floor) where liquid detection is desired. If tape is required to hold the sensor in place, be sure to only apply tape to the ends, exposing as much of the sensor as possible. At least 5/8" of the sensor must be exposed for it to function.

NTI E-LD50-100 Liquid Detection Sensor, Plenum Rope-Style - Length of water sensor cable - 50 ft. Length of 2-wire cable - 100 ft. Features:

  • For detecting water presence and warning of flooding.
  • 100% waterproof electronics.
  • Detects any conductive liquid or moisture.
  • Minimum puddle: 0.6" (15 mm) diameter.
  • Detects liquid depth >0.1" (2.5 mm).

Why not buy this NTI E-LD50-100 Liquid Detection Sensor, Plenum Rope-Style - Length of water sensor cable - 50 ft. Length of 2-wire cable - 100 ft. today?

NTI E-LD50-100 Liquid Detection Sensor, Plenum Rope-Style - Length of water sensor cable - 50 ft. Length of 2-wire cable - 100 ft. Specifications:

  • Voltage and current:
    • Open Circuit: 5VDC max @ 1µA.
    • Closed circuit: <300mV @ 10.7mA.
  • Available water sensor cable (x) lengths: 1/10/50/100/200/400/600/800/1000 feet.
    • Plenum rating: CL2P (UL)
    • Diameter: 0.25 in (6.35mm)
    • Bend radius: 0.375 in (9.53 mm)
    • Operating temperature: 32 to 167°F (0 to 75°C).
  • Available 2-wire plenum cable (y) lengths: 5/10/20/50/100 feet.
    • Insulation and Outer Jacket Material: Plenum Grade PVC
    • Diameter: 0.111 in (2.82 mm)
    • Contact an NTI product consultant for cable lengths over 100 feet (30 meters) - supports up to 1,000 feet (305 meters).
  • Regulatory approvals: CE, RoHS
  • MTBF: 10,869,188 hrs
  • Use self-adhesive clips (E-CLPxx-LD) to prevent sensor rope cable from shifting after installation

Why not buy this NTI E-LD50-100 Liquid Detection Sensor, Plenum Rope-Style - Length of water sensor cable - 50 ft. Length of 2-wire cable - 100 ft. today?

E-LD50-100 User Manual

Why not buy this NTI E-LD50-100 Liquid Detection Sensor, Plenum Rope-Style - Length of water sensor cable - 50 ft. Length of 2-wire cable - 100 ft. today?

Frequently Asked Questions
Reasons To Buy an NTI Product