Kramer BCLS-31YL-5 CAT 6A U/UTP 23AWG 650MHz Bulk Cable

Kramer

Price: $1,054.00
Today's Price: $843.20

10% Discount. Apply Code 10percentOff at Checkout!

Part Number:
BCLS-31YL-5
UPC:
7291063073565
Availability:
Usually ships the same day
1:
Kramer BCLS-31YL-5 CAT 6A U/UTP 23AWG 650MHz Bulk Cable
2:
23AWG solid bare copper
3:
With rip cord & cross filler
4:
Free Shipping
10:
Free1-Year Kramer Warranty
5:
Free Lifetime Telephone, CHAT, Text, Fax & Email Tech Support

Kramer BCLS-31YL-5 CAT 6A U/UTP 23AWG 650MHz Bulk Cable - Low Smoke & Halogen Free is a high-performance CAT6A U/UTP cable designed for IT, LAN and Ethernet installations. It is constructed with four pairs of 23AWG solid bare copper conductors with a cross filler in an LSZH jacket with internal rip cord and sequential markings every meter and packed on a fumigated plywood reel. The unique zigzag jacket design provides excellent performance of "six around one" bundle transmission. BCLS-31 cable exceeds CAT 6A specifications to provide additional performance and bandwidth beyond the basic standard.

Kramer BCLS-31YL-5 CAT 6A U/UTP 23AWG 650MHz Bulk Cable - Low Smoke & Halogen Free

  • High-Performance Single Cable Transmission.
  • Zigzag Jacket Design - Provides excellent performance of six around one bundle transmission.
  • Round & Smooth Jacket without Twisted Stripe.
  • High-Quality Safety Properties.
  • Sweep Frequency up to 650MHz.

Why not buy this Kramer BCLS-31YL-5 CAT 6A U/UTP 23AWG 650MHz Bulk Cable - Low Smoke & Halogen Free today?

Kramer BCLS-31YL-5 CAT 6A U/UTP 23AWG 650MHz Bulk Cable - Low Smoke & Halogen Free

  • CONSTRUCTION
    • Conductor: 4 pairs of 23AWG solid bare copper
    • Insulation: Polyolefin (PO)
    • Insulation: blue & white, orange & white, green & white, brown & white
    • Twist: Left-hand
    • Assembly: Left hand direction
    • Rip Cord: Polyester multi-yarn
    • Jacket: Low smoke zero halogen (LSZH), yellow (Pantone 116C)
  • FILLER: Polyolefin (PO)
  • DIAMETERS
    • Jacket: Diameter: 8.3 ±0.2mm
    • Jacket: thickness: 1.10 ±0.01mm
    • Insulation: Blue & white: 1.17 ± 0.02mm
    • Insulation: Orange & white: 1.12 ± 0.02mm
    • Insulation: Green & white: 1.15 ± 0.02mm
    • Insulation: Brown & white: 1.10 ± 0.02mm
  • ELECTRICAL
    • Temperature & Voltage Rating: 60˚C @300V
    • Spark Test: 2.5kV DC
    • AC Leakage Current: =10mA (1.5kV AC) through overall jacket
    • Conductor DC Resistance: =9.38? /100m
    • Resistance Unbalance: =5%
    • Dielectric Strength: 1.5kV AC for 2sec
    • Insulation Resistance: =5000M? /m
    • Mutual Capacitance: =5.6nF /100m
    • Capacitance Unbalance: =330pF /100m pair-to-ground
    • Characteristic Impedance: 100±15? @1~100MHz
    • Coupling Attenuation: =55dB @30MHz, =41dB @500MHz
  • USAGE AND ENVIRONMENTAL
    • Cable Cold Bend: -20˚C for 4hr
    • Insulation Tensile Strength: 2400 PSI min. (1.69kg/m.sq)
    • NVP: 67%
    • Temperature Range: Storage & shipping: - 20˚C to 60˚C
    • Temperature Range: installation: 0˚C to 60˚C
    • Temperature Range: operation: -20˚C to 60˚C
    • Minimum Bending Radius: =4 times of overall diameter
    • Maximum Pulling Tension: =110N
  • REGULATORY PERFORMANCE
    • ANSI/TIA-568-C.2 (2009): Balanced Twisted-Pair Telecommunications Cabling and Components Standards
    • ISO/IEC 11801 (Edition 2.2): Information technology - Generic cabling for customer premises
    • IEC 61156-5 (Edition 2.0): Multicore and symmetrical pair/quad cables for digital communications - Part 5: Symmetrical pair/quad cables with transmission characteristics up to 1000 MHz - Horizontal floor wiring - Sectional specification
    • EN 50288-6-1:2013: Multi-element metallic cables used in analogue and digital communication and control - Part 6-1: Sectional specification for unscreened cables characterized up to 250MHz - Horizontal and building backbone cables
  • REGULATORY SAFETY
    • EN 50173-1:2011: Information technology - Generic cabling systems - Part 1: General requirements
    • IEC 60332-1-2: Tests on electric and optical fiber cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1kW pre-mixed flame
    • IEC 61034-1 / 61034-2: Measurement of smoke density of cables burning under defined conditions
    • IEC 60754-2: Test on gases evolved during combustion of materials from cables